Crystal Quest Authorized dealer

SKU: SWP-H80B4

H-Flow High-Pressure Pump H80-4S

In stock
Regular price $12,279.99

Ships direct from the manufacturer · Shipping calculated at checkout Details

Returns within 30 days of delivery · 30% restocking fee Details

Questions? Talk to a water specialist

Overview

Product Description

The H-Flow High-Pressure Pump H80-4S is a high-capacity, robust pump engineered for industrial, commercial, and agricultural applications. Powered by a 5HP motor, this pump delivers reliable performance and exceptional efficiency for demanding environments requiring consistent water flow and pressure.

H-Flow High-Pressure Pump H80-4S

Cast Iron / Stainless Steel – 80 GPM – 4 Stage – 5 HP / 1 Phase

Technical Specifications
Model H-Flow High-Pressure Pump H80-4S
Nominal Flow Rate 80 GPM
Stages 4
Motor RPM 3500 RPM
Motor Frame NEMA JM Frame Motor (C-Face)
HP Rating 5 HP
Phase / Hertz 1 PH / 60 Hz
Inlet 1½″ FNPT
App. Dimensions (A x B) 19.70″ x 12.97″
App. Weight (lb) 141

Parts And Components

Construction & Design Features

Component Description
Inlet / Motor Bracket Cast Iron
Discharge Housing Steel
Pump Housing 304 Stainless Steel Tubing
Impellers Noryl
Diffusers Noryl
Wear Rings 316 Stainless Steel
Shaft & Coupling 316 Stainless Steel / 415 Stainless Steel
Shaft Bearing Sleeve 316 Stainless Steel
Shaft Bearing Bronze
Mechanical Seal Carbon/Ceramic
Mechanical Seal Spacer 416 Stainless Steel
O-Rings Buna-N

Installation Instructions

Installation Manual

Installation Instructions

  1. Preparation:
    • Inspect the pump for any damage and verify that all components are included.
    • Ensure the motor voltage matches the power supply specifications.
    • Check the alignment of the pump and motor before installation.
  2. Foundation:
    • Mount the pump on a flat, stable surface to reduce vibrations during operation.
    • Secure the pump using anchor bolts to ensure stability.
  3. Piping Connections:
    • Connect suction and discharge pipes using appropriate gaskets and seals.
    • Support the piping to prevent stress on the pump connections.
    • Install a check valve and isolation valve on the discharge side for operational control.
  4. Priming the Pump:
    • Fill the pump casing with liquid to ensure proper priming before starting.
    • Use the vent valve to eliminate trapped air in the pump casing.
  5. Electrical Wiring:
    • Wire the motor according to local electrical codes and safety standards.
    • Ensure the motor is properly grounded for safe operation.
    • Verify that the motor rotation matches the direction indicated on the pump casing.
  6. Startup:
    • Fully open the suction and discharge valves before starting the pump.
    • Start the motor and observe the pump for any irregularities.
    • Check for leaks, vibrations, or unusual noises during startup.
  7. Final Adjustments:
    • Adjust the flow and pressure as needed using the discharge valve.
    • Avoid throttling the suction side to maintain pump efficiency.
  8. Regular Maintenance:
    • Periodically inspect the pump and motor for wear or damage.
    • Lubricate bearings and other components as per the manufacturer’s recommendations.

Shipping, Warranty & Returns

Shipping is calculated at checkout by weight.

Orders ship direct from the manufacturer. We submit your order within 2 business days and email tracking as soon as it ships.

Estimated transit once shipped: 1–5 business days.

Alaska, Hawaii and Puerto Rico: ask us for a shipping quote.

Checkout offers this item to the contiguous 48 states and DC. For Alaska, Hawaii or Puerto Rico, use the shipping quote form or call 908-787-6030 and we reply by email with the delivered price. Nothing is charged until you accept.

Shipping details

1-year manufacturer warranty. We handle the claim for you from start to finish. Crystal Quest warranty terms

Start a warranty claim

Contact us for a Return Authorization (RMA) before sending anything back. We can't accept returns without one.

  • Start your return within 30 days of delivery. Approved returns carry a 30% restocking fee. Reverse osmosis systems, filter cartridges, membranes and media can't be returned.
  • Items must be unopened, unused and resellable, with all original packaging and components. You pay return shipping.
  • Systems, filters, cartridges and membranes can't be returned once water has run through them or they have been installed. Hygienic products can't be returned once opened.
  • Damaged or defective on arrival? Contact us within 48 hours with photos and we arrange the return.

Return terms for Crystal Quest

Documents & Manuals