Overview

Product Description

The H-Flow High-Pressure Pump H35-12S is part of the EZ Series Booster Pump line, offering high-performance solutions for industrial, commercial, and agricultural applications. With 1.5HP motor power and stainless steel construction, this pump is designed to deliver reliable and efficient operation.

H-Flow High-Pressure Pump H35-5S

Cast Iron – 35 GPM – 12 Stage – 3 HP

Technical Specifications
Model H-Flow High-Pressure Pump H35-12S
Nominal Flow Rate 35 GPM
Stages 12
Motor RPM 3500 RPM
Motor Frame 56J (C-Face)
HP Rating 3 HP
Phase / Hertz 1 PH / 60 Hz
Inlet 1½″ FNPT
Dimensions (A x B) 24.82″ x 13.63″

Parts And Components

Construction & Design Features

Component Description
Inlet / Motor Bracket Cast Iron
Discharge Housing Cast Iron
Pump Housing 304 Stainless Steel
Impellers Thermoplastic
Diffusers Thermoplastic
Wear Rings 316 Stainless Steel
Shaft & Coupling 316 Stainless Steel
Mechanical Seal Carbon/Ceramic
O-Rings Buna-N

Installation Instructions

Installation Manual

Installation Instructions

  1. Preparation:
    • Ensure the installation site is clean, dry, and has sufficient ventilation.
    • Verify that the power supply matches the pump's electrical requirements (3 HP motor, 60 Hz, 3500 RPM).
    • Ensure all piping and fittings are compatible with the pump's inlet and discharge sizes (1½″ NPT).
  2. Mounting:
    • Secure the pump on a stable, level surface to prevent vibrations during operation.
    • If the pump has a support bracket (14+ stages), ensure it is mounted approximately 4 inches from the discharge for added stability.
  3. Piping Connections:
    • Connect the suction pipe to the inlet, ensuring an airtight seal to prevent cavitation.
    • Connect the discharge pipe to the outlet, ensuring proper alignment to avoid stress on the pump housing.
    • Install a check valve and isolation valves on both the suction and discharge lines for easy maintenance.
  4. Electrical Connection:
    • Use a certified electrician to connect the pump to the power source.
    • Follow all local electrical codes and guidelines for safety.
    • Ensure the motor is properly grounded.
  5. Priming the Pump:
    • Fill the pump casing with water through the priming port to eliminate air pockets.
    • Ensure all air is purged from the suction line.
  6. Testing:
    • Turn on the pump briefly to check for proper rotation (refer to the motor manual).
    • Inspect all connections for leaks or vibrations.
    • Run the pump at full capacity and monitor for stable operation.
  7. Maintenance Tips:
    • Regularly inspect the pump for wear or leaks.
    • Clean or replace the mechanical seal and wear rings as needed.
    • Follow the manufacturer's maintenance schedule for optimal performance.

Shipping, Warranty & Returns

Shipping is calculated at checkout by weight.

Orders ship direct from the manufacturer. We submit your order within 2 business days and email tracking as soon as it ships.

Estimated transit once shipped: 1–5 business days.

Alaska, Hawaii and Puerto Rico: ask us for a shipping quote.

Checkout offers this item to the contiguous 48 states and DC. For Alaska, Hawaii or Puerto Rico, use the shipping quote form or call 908-787-6030 and we reply by email with the delivered price. Nothing is charged until you accept.

Shipping details

1-year manufacturer warranty. We handle the claim for you from start to finish. Crystal Quest warranty terms

Start a warranty claim

Contact us for a Return Authorization (RMA) before sending anything back. We can't accept returns without one.

  • Start your return within 30 days of delivery. Approved returns carry a 30% restocking fee. Reverse osmosis systems, filter cartridges, membranes and media can't be returned.
  • Items must be unopened, unused and resellable, with all original packaging and components. You pay return shipping.
  • Systems, filters, cartridges and membranes can't be returned once water has run through them or they have been installed. Hygienic products can't be returned once opened.
  • Damaged or defective on arrival? Contact us within 48 hours with photos and we arrange the return.

Return terms for Crystal Quest

Documents & Manuals